DITYPUMP

Portable compressor for DITYSPRAY

990001

By box unit

An additional device in the form of a compact, easy-to-carry case offering the option of mobile use. It consists of a compressor for autonomous compressed air access, a DITYBOX and has a capacity of up to four DITYBAGs ! Fully charged, its battery will allow you to recharge your DITYBOX fully up to 27 times.

More details

199,00 €


Data sheet

PackagingPer unit
Product typeTechnical product, DITYSPRAY System
Application domainMaintenance, Surface maintenance, Surfaces cleaning, Complementary products, Preparion of the supports

More info


DISCOVER THE DITYSPRAY SYSTEM

 

The DITYSPRAY refillable spray can system is a real revolution and alternative to the classic aerosol. Today, this system is the only air conditioning solution that uses compressed air as a propulsion force in a rechargeable and transparent suitcase ! It is ideal for confined or high-risk working environments and allows all kinds of products to be applied while respecting people and the environment.

 

KNOW MORE ABOUT THE DITYPUMP

 

The suitcase equipped with a compressor for an autonomous and mobile access to compressed air, rechargeable on sector or cigar lighter. It also comes with a DITYBOX.

Ditypump portable case for Dityspray system

 

SEE THE INSTRUCTIONS FOR USE

SPECIFICATIONS OF THE DITYPUMP

  • Working pressure and maximum service pressure = 8 bar. Test pressure = 12 bar.
  • Maximum and minimum design temperature TS min / TS max = -5°C / +60°C. Volume V = 0.58L.
  • Pressurisation fluid = air. PED 97/23/EC category = 3.3 - « Conforming to the European directive PED 97/23/EC according to category 3.3 ».

RECOMMENDATIONS ON THE MAXIMUM TEMPERATURE AND PRESSURE

In normal use, DITYBOX is designed to operate at a maximum pressure of 8 bar at temperatures between -5°C and +60°C. These pressure and temperature limits must not be exceeded. Overpressure of the DITYBOX (exceeding 8 bar) or exposure to extreme temperatures (below-5°C or above 60°C) may present risks for the user.

You can learn more about the strength of the DITYBOX by reading our section on DITYSPRAY system tests.

 

DITYBOX AND DITYBAG STORAGE CONDITIONS

shelter from the cold, sunlight and rain.

 

CONDITIONS OF USE

avoid shocks to the DITYBOX.

 

PRESSURIZATION CONDITIONS

  • Pressurize to a maxi-mum of 8 bars.
  • Pressurize with air only.
  • Use only DITYSPRAY consumables.

 

WHAT NOT TO DO

  • Do not use a DITYBOX that appears cracked.
  • Do not use a leaking DITYBOX.
  • Do not attempt to repair a damaged DITYBOX.
  • Do not attempts to open the spray before it is empty.
  • DO NOT CHARGE THE DITYBOX WHEN THE COMPRESSOR IS CHARGING.

 

Guaranteed 3 years parts and workforce.

  DITYSPRAY System

DITYPUMP INSTRUCTIONS FOR USE

1 Ditypump unscrew nut1) Screw out the empty DITYBOX cap.
2 Ditypump introduce ditybag2) Screw out the DITYBAG cap and fill it into DITYBOX.
3 Ditypump screw nut3) Screw in cap onto DITYBOX to make airtight the system.
4 Ditypump switch on compressor4) Switch on the power by pressing On/Reset button and select unit by pressing it again.
5 Ditypump set to 5 bars5) Adjust pressure level at 5 bars by pressing the Up / Down button. When you stop pushing it, the digital on display will flash 3 times to indicate a pressure level has been set. Then, it will go back to 0. It is ready to inflate.
6 Ditypump air-charging6) Match the connection of the inflating valve of DITYBOX on the compressor and press it down to supply in air. Press the trigger again to stop or the compressor will automatically stopped when the pressure reached the preset pressure. Always switch off the device properly after the device auto-stopped.
7 Spray your product7) Spray your product
8 Ditypump depressurize8) Screw out the cap of DITYBOX.
9 Ditypump unscrew nut9) Screw out the cap of DITYBOX.
10 Ditypump remove ditybag10) Take out DITYBAG and close the cap.
11 Ditypump screw in ditybox nut11) Screw in the cap on DITYBOX.

Associated products