DITYBOX

Container for DITYSPRAY

990000

By box unit

The DITYBOX is a box / container for the DITYSPRAY system. It is highly secure and totally hermetic once charged with air. It offers a very high resistance to shocks or high pressures and guarantees daily use (reusable up to 5000 times). Its air supply valve located under the housing can be connected to any type of air network.

More details

50,00 €


Data sheet

Packaging1 per box
Product typeTechnical product, DITYSPRAY System
Application domainMaintenance, Surface maintenance, Surfaces cleaning, Complementary products, Preparion of the supports

More info


DISCOVER THE DITYSPRAY SYSTEM

 

The DITYSPRAY refillable spray can system is a real revolution and alternative to the classic aerosol. Today, this system is the only air conditioning solution that uses compressed air as a propulsion force in a rechargeable and transparent case ! It is ideal for confined or high-risk working environments and allows all kinds of products to be applied while respecting people and the environment.

 

KNOW MORE ABOUT THE DITYBOX

 

Approved transparent TR90 housing that is shock- and wear-resistant, and reusable. DITYBOX is the receptacle for DITYBAGS. DITYBOX has a valve
at its base for compressed air supply. The product is propelled by the compressed air pressure on the DITYBAG. A screw-tightening ring is used to seal the system.

Ditybox Box

 

SEE THE INSTRUCTIONS FOR USE

SPECIFICATIONS OF THE DITYBOX

  • Working pressure and maximum service pressure = 8 bar. Test pressure = 12 bar.
  • Maximum and minimum design temperature TS min / TS max = -5°C / +60°C. Volume V = 0.58L.
  • Pressurisation fluid = air. PED 97/23/EC category = 3.3 - « Conforming to the European directive PED 97/23/EC according to category 3.3 ».

 

RECOMMENDATIONS ON THE MAXIMUM TEMPERATURE AND PRESSURE

In normal use, DITYBOX is designed to operate at a maximum pressure of 8 bar at temperatures between -5°C and +60°C. These pressure and temperature limits must not be exceeded. Overpressure of the DITYBOX (exceeding 8 bar) or exposure to extreme temperatures (below-5°C or above 60°C) may present risks for the user.

You can learn more about the strength of the DITYBOX by reading our section on DITYSPRAY system tests.

 

DITYBOX AND DITYBAG STORAGE CONDITIONS

shelter from the cold, sunlight and rain.

 

CONDITIONS OF USE

avoid shocks to the DITYBOX.

 

PRESSURIZATION CONDITIONS

  • Pressurize to a maxi-mum of 8 bars.
  • Pressurize with air only.
  • Use only DITYSPRAY consumables.

 

WHAT NOT TO DO

  • Do not use a DITYBOX that appears cracked.
  • Do not use a leaking DITYBOX.
  • Do not attempt to repair a damaged DITYBOX.
  • Do not attempts to open the spray before it is empty.
  • DO NOT CHARGE THE DITYBOX WHEN THE COMPRESSOR IS CHARGING.

 

Guaranteed 3 years parts and workforce.

  DITYSPRAY System

 

 DITYBOX INSTRUCTIONS FOR USE

1 Ditybox unscrew nut1) Screw out the empty DITYBOX cap.
2 Ditybox introduce ditybag2) Screw out the DITYBAG cap and fill it into DITYBOX.
3 Ditybox screw nut3) Screw in cap onto Ditybox to make airtight the system.
4 Ditybox connect valve4) Match the connection of the inflating valve of DITYBOX to a compressed air network or on the compressor and supply it with air until a pressure of 5 bar is reached.
5 Ditybox product release5) Spray your product.
6 Ditybox empty air6) Empty the remaining air by pressing the DITYBOX’s inflation valve or by connecting it to the deflation tip of your compressor.
7 Ditybox unscrew nut7) Screw out the cap of DITYBOX.
8 Ditybox remove ditybag8) Take out DITYBAG and close the cap.
9 Ditybox screw back nut9) Screw in the cap on DITYBOX.

 


Associated products